Diaphragm control
| In case of a diaphragm rupture, the pumped liquid can enter the air side of the pump and exit through the air exhaust. Such a leakage can be avoided when using a diaphragm control. Both air chambers have sensors which registrate entering liquid. These sensors transmit an impulse to a level controller which stops the pump and/or activates an alarm signal. The use of a diaphragm control is only possible with conductive liquids. The diaphragm control is available for following types at extra costs: - DMP 3/8"
- DMP 1/2"
- DMP 1"
- DMP 1 1/2 and DMP 2"
- DMP 3"
|
Weitere Information:
URL:
http://www.lutz-pumpen.de/en/desktopdefault.aspx/tabid-267/372_read-2482/
Lutz Pumpen GmbH
Erlenstrasse 5-7
DE-97877 Wertheim
Deutschland
Phone Tel.: +49 (0)9342 8 79-0
Fax: +49 (0)9342 87 94 04
Email E-Mail: info@lutz-pumpen.de
Internet Web: www.lutz-pumpen.de