LogoLutz

Flow meter TS with volume preselection for highly inflammable liquids

Lutz Flow Meter TS

Flow meter TS with volume preselection for highly inflammable liquids

Liquid examples:
Methanol, gasoline, isopropanol, kerosene, formic acid, acetic acid, acetone, styrene, xylene, toluene, etc.

Features:

  • Suitable for easily inflammable liquids and many aggressive fluids
  • Nutating disc principle 
  • Mobile on a drum pump or in stationary process applications
  • For thin-bodied and viscous liquids
  • Displays partial and total volume
  • Suitable for flow rates from 10 l/min to 120 l/min 
  • Available in plastic (PPS) or metal (SS, HC)
  • Unmistakeable plug-type connectors 
  • Explosion-proof in compliance with ATEX Directive 94/9/EC, category 2

 

 

TS/RM Ex

 

Types:

  • Type LM / Ex-RM 1m K for easily inflammable solvents
  • Type UN / Ex-RM 1m for easily inflammable and aggressive liquids
  • Type VA I / Ex-RM 1m for easily inflammable and aggressive liquids

     

Benefit:

  • Convenient, user-friendly display with numeric keypad
  • Basic flow meter electrically conductive
  • No special knowlege for installation required
  • Simple, modular construction 
  • Easy operation
  • Keyboard lock as protection against maloperation
  • System protection through failure detection
 

Type LM/RM

Type UN/RM

Type VA I/RM Ex

Housing:

PPS PPS Stainless steel (1.4581)
Measuring chamber: LCP LCP Stainless steel
Nutating disc: LCP LCP Stainless steel/ETFE
Magnet: BaFe/brass/1.4401 PPS encapsulated  ETFE encapsulated
Seals: Viton® Viton® Viton®-FEP
Range of measurement: 10-100 l/min* 10-100 l/min* 10-100 l/min
Range of viscosity: max. 2000 mPas max. 2000 mPas max. 5000 mPas
Operating pressure: max. 4 bar max. 4 bar max. 10 bar
Accuracy: +/- 1% +/- 1% +/- 1%
Temperature: max. 40 °C max. 40 °C max. 40 °C
Connection: G 2 / G 1 1/4 G 2 / G 1/4 G 1 1/4 / G 1 1/4

Identification
Operating unit:
Basic flow meter:

 

II 2 G Ex ib IIB T4
II 2 G T4

 

II 2 G Ex ib IIB T4
II 2 G T4

 

II 2 G Ex ib IIB T4
II 2 G T4

       

Relay module
Ex RM 1 m
 

     

Voltage: 

220-240V 

220-240V 

220-240V 

Frequency: 

50-60 Hz  

50-60 Hz

50-60 Hz

Switching outputs: 
Identification:  II 2 G Ex me [ib] IIC T4 II 2 G Ex me [ib] IIC T4 II 2 G Ex me [ib] IIC T4

* short-time 120 l/min

 

LM/RM

Fig. 1: Flow meter TS with volume preselection, Type LM / Ex-RM 1m K

VA I Ex/RM

Fig. 2: Flow meter TS with volume preselection, Type VA I / Ex-RM 1m K

 

TS/RM Ex

Fig. 3: Flow meter TS with volume preselection in a hazardous location

SeparatorLine

Weitere Information:

URL:
http://www.lutz-pumpen.de/en/desktopdefault.aspx/tabid-27/117_read-70/232_page-2/

Lutz Pumpen GmbH
Erlenstrasse 5-7
DE-97877 Wertheim
Deutschland
Phone Tel.: +49 (0)9342 8 79-0
Fax: +49 (0)9342 87 94 04
Email E-Mail: info@lutz-pumpen.de