for mounting on pump type B1/B2 Battery and B2 Vario
Ideal for measuring highly aggressive acids and alkalis and many other non-flammable liquids.
Liquid examples: Sodium hypochlorite, nitric acid, sulphuric acid, etc.
Features:
- Measurement according to the turbine wheel principle
- For thin-bodied fluids
- Display of the partial and total volume
- Range of measurement from 5 l/min - 120 l/min
- Mobile installed on a drum pump or with nozzle connection
Note: This meter replaces our previous TR90 model.
Suitable media: | Eisen-III-Chlorid, Glykol, Phosphorsäure, Salzsäure |
Housing Material: | PP (polypropylene) |
Measuring chamber (material): | PP (Polypropylen), PVDF (Polyvinylidenfluorid) |
Seals (material): | PTFE (polyvinylidene fluoride) |
Temperature of medium (up to °C): | 50 |
Flow rates (up to l/min): | 120 |
Operating pressure (max. bar): | from 8 bar |
Messgenauigkeit kalibriert**: | ± 1% |
Wiederholgenauigkeit (%): | ± 0,5 |
Viscosity (up to mPas): | 40 |
Operating pressure (max. bar): | from 8 bar |
Protection type: | IP65 |
Connecting threads: | 1", 1 1/4" |
Type: | TR3-PP |
Version: | Mounting on B1/B2 Battery / B2 Vario, Mounting on drum pump, Installation on nozzle |
Scope of delivery: | TR3-PP |
* Die max. Fördermenge ist ein ermittelter Wert mittels Prüfstand und gemessen mit Wasser bei einer Mediumstemperatur von ca. 20° C. Die Messung erfolgt am Druckstutzen der Pumpe, ohne Schlauch, Zapfpistole oder Durchflussmesser. Die im Einsatz erzielbare Fördermenge ist niedriger und hängt von der individuellen Anwendung, den Medieneigenschaften sowie der Konfiguration der Pumpe ab. Die max. Förderhöhe ist ebenso abhängig von Pumpenausführung, Motor und Medium. Die Viskositätswerte werden mit Öl ermittelt. ** Prüfaufbau: Medium Wasser / Diesel, Durchfluss in Vorzugsrichtung, Beruhigungsstrecke 0,2 m vor und nach dem Durchflusszähler