Material: Polyethylene (PE)
Diaphragm / valve balls / seals material: PTFE / PTFE / EPDM
Center block material: Polypropylene glass fiber reinforced (PP)
Material explanation: EPDM = ethylene propylene diene rubber, FPM = Fluorine rubber,
NBR = acrylonitrile butadiene rubber, PP = polypropylene, PTFE = polytetrafluoroethylene,
TPC-ET + TFM (PTFE) = Thermoplastic polyester elastomer + Modified polytetrafluoroethylene,
TPV (EPDM-PP) = EPDM/PP compound
Description:
The double diaphragm pump is suitable for food and pharmaceutical applications, as well as large flow rates and higher viscosities.
- typical applications: liquid food and luxury food, pharmaceutical agents and cosmetic products
- highly resistant PE material with low coefficient of friction
- FDA compliant
Features & Advantages
- high hydraulic performance
- maintenance optimized design and easy installation
- self-priming (even in dry condition)
- ice-free air system
- blockage-free operation
- food safe connections
Double diaphragm pumps (material): | non - metallic |
Carcasa (material): | PE (Polyethylen) |
Centre block (material): | Polypropylene glass fibre reinforced (PP) |
Diafragmas (material): | PTFE (fluoruro de polivinilideno) |
Válvula de bola (material): | PTFE (Polytetrafluorethylen) |
Sellos (material): | EPDM (etileno-propileno-dieno-monómero) |
Asiento de válvula (material): | PE (Polyethylen) |
Caudal (hasta l/min): | 370 |
Cabezal de salida (hasta mWS): | 80 |
Sólidos (ø máx. mm): | 7 |
Temperatura del fluido (máx. °C): | 60 |
Viscosidad (hasta mPas): | 30000 |
Suction head dry (up to max. mwc*): | 4,5 |
Air pressure (max. bar): | 8 |
Air pressure start-up (min. bar): | 2 |
Sound pressure level dB(A): | 80 |
Displacement per chamber (in cm³): | 670 |
Displacement per chamber (in cm³): | 1340 |
Tamaño: | 1 1/2" |
Air inlet (inch) inside: | 1/2" |
Druckstutzen (DN): | 40 |
Saugstutzen (DN) : | 40 |
Connection: | Flansch |
Certificación: | FDA-compliant |
Tipo: | DMP 1 1/2" PEE Pure PE/EPDM |
* El caudal máximo es un valor determinado mediante un banco de pruebas y medido con agua a una temperatura media de aprox 20°C. La medición se realiza en la junta de presión de la bomba, sin manguera, boquilla ni caudalímetro. El caudal que se puede alcanzar en uso es menor y depende de la aplicación individual, las propiedades del medio y la configuración de la bomba. La altura máxima depende del tipo de la bomba, el motor y el liquido. Los valores de viscosidad se determinan con aceite. ** Comprobación: Liquido agua / diesel, flujo en dirección preferente, distancia de calma 0,2 m antes y después del contador